EasyManuals Logo

UEi DL489 User Manual

UEi DL489
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
6
A. Clamp: Measure inductive AC/DC current. Opens to 1.25” (31.7mm).
B. Conductor Alignment Marks: Use to aid the visual alignment of a conductor
when measuring inductive amperage. Greatest accuracy is achieved when the
conductor inside the clamp is centered at the intersection of these marks.
C. Wire Separation Tab/ NCV sensor: Use to isolate an individual wire from a
bundle for testing. NCV sensor detects live voltage.
D. Test Lead Holder: Used for hands-free use of the test probes.
E. Worklight: Lights clamp area in dark work environments.
F. Category Max Indicator: Maximum CAT Rating for clamp jaw.
G. Hand Guide: Used as a point of reference for the operator’s safety.
H. Clamp Lever: Opens and closes current clamp jaw.
NOTE: The clamp uses a high-tension spring to close the jaw. Do not allow
fingers or objects to become pinched in the base as the jaws close.
I. NCV Alert Light: Indicates voltage when in NCV mode and high-voltage alert.
J. Hold/Worklight/ Back light Button:
• Press to hold the reading on the display. Press again to return to live reading.
• Press and hold to turn on Worklight and Back light. Press and hold again to
turn off.
Worklight and Backlight turn off after 60 seconds.
K. NCV Button: Press and hold for Non-contact voltage detection mode.
L. AC/DC Amps/ Microamps Button:
• Press to enter AC/DC Amps mode; (AC/DC Amps upper display)
• Press again to enter AC/DC Microamps (µA) mode; (AC/DC microamps lower
display),
M. Temperature Button:
• Press to enter temperature mode for T1 (upper temperature input jack).
• Press again to enter temperature mode for T2 (lower temperature input jack).
• Press again to enter temperature differential mode (T1-T2).
• Press and hold to change temperature scale.
N. Range Button:
• Press to toggle to between Auto and Manual Ranging modes. (AT will
appear on display when in Auto Ranging mode).
• Press repeatedly to cycle through manual ranges when in Manual Ranging
mode.
• Press and hold to return to auto ranging mode.
Note: Select range prior to MIN/MAX for best results.
O. Power Button: Press to turn on and off the meter.
P. Min/Max/ Peak Button:
• Press to enter Min/Max mode. Max is the default setting.
• Press repeatedly to cycle through Min/Max captured values.
• Press and hold to return to live readings.
• Press and hold to enter Peak mode.
• Press and hold again to return to live readings.
Q. AC/DC Volts/ Hertz (Hz)/ Duty Cycle Button:
• Press to enter AC Voltage mode.
• Press again to enter DC Voltage mode.
• Press and hold to enter Hertz (Hz)/Duty Cycle modes.
• Press to return to live readings.
R. Continuity/ Resistance/ Capacitance/ Diode Test Button:
• Press to enter Continuity mode.
• Press again to enter Resistance mode.
• Press again to enter Capacitance mode.
• Press again to enter Diode test mode.
• Press again to return to live readings.
OVERVIEW (CONT.)