FEATURES
True RMS
600A AC/DC
750V AC/1000V DC
Resistance 60MΩ
Capacitance 2000µF
AC/DC microamps 2000µA
Frequency 99.99kHz
Dual Temperature Differential
Non-Contact Voltage
LRA Inrush
Data hold
Min/Max
Peak hold
Visible high-voltage alert
Manual ranging option
Worklight/ back lit display
Low battery indicator
Auto power off
Magnetic mount
Dual display
Input jack locks
Detachable clamp head
GENERAL SPECIFICATIONS
Operating Temperature: 32˚ to 122˚F (0˚ to 50˚C)
Storage Temperature -4˚F to 140˚F (-20˚ to 60˚C)
Operating Humidity: <80%
Operating Altitude: 6,562 ft (2,000m)
Pollution Degree: 2
Display: 3 5/6 digits, 6,000 count
Refresh Rate: 3/sec
Over-range: “OL” is displayed
Dimensions: 10.2” X 2.5” X 1.5”
Item Weight: 1 lb.
Calibration: Recommended annually
CAT Rating: CAT III 600V/CAT II 1000V
Certifications: cETLus 3rd Edition, CE Conformity, IEC 61010-1 3rd Edition,
IP42, 6’ Drop Protetion, RoHS,
Battery Type: (AAA) X 6
Test Leads: Test leads w/alligator clips CATIV 600V/CATII 1000V
IMPORTANT SAFETY WARNINGS
WARNING
Read entire Safety Notes section regarding potential hazard and proper
instructions before using this meter. In this manual the word “WARNING” is
used to indicate conditions or actions that may pose physical hazards to the
user. The word “CAUTION” is used to indicate conditions or actions that may
damage this instrument.
WARNING
To ensure safe operation and service of the tester, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
WARNING
Before each use, verify meter operation by measuring a known voltage
or current.
Never use the meter on a circuit with voltages that exceed the category
based rating of this meter.
Do not use this meter during electrical storms or in wet weather.
Do not use the meter or test leads if they appear damaged.
Ensure meter leads are fully seated and keep fingers away from the
metal probe contact when making measurements. Always grip the leads
behind the finger guards molded into the probe.
Do not open the meter to replace batteries while the probes are
connected.