9
Features:
RANGE
MIN/MAX
HOLD
SEL
ACμA
Ranges Accuracy Resolution Overload Protection
600μA to 6000μA ±(1.2% +5 dgts) 0.1μA to 1μA 600mA /1000V Fast Fuse
Minimum sensitivity: 50μA AC (auto selection mode only)
DCμA
Ranges Accuracy Resolution Overload Protection
600μA to 6000μA ±(1.0% +3 dgts) 0.1μA to 1μA 600mA /1000V Fast Fuse
Minimum sensitivity: 50μA DC (auto selection mode only)
ACmA
Ranges Accuracy Resolution Overload Protection
60mA to 400mA ±(1.2% +5 dgts) 0.01mA to 0.1mA 600mA /1000V Fast Fuse
Minimum sensitivity: 5mA AC (auto selection mode only)
DCmA
Ranges Accuracy Resolution Overload Protection
60mA to 400mA ±(1.0% +3 dgts) 0.01mA to 0.1mA 600mA /1000V Fast Fuse
Minimum sensitivity: 5mA DC (auto selection mode only)
AC/DC Microamps: 6000μA AC/DC Milliamps: 400mA