Details on quick disconnect fittings and suction feet for the table-top unit, including part numbers.
Instructions for securing the wall mount, including recommendations for stud finders and drywall anchors.
Procedure for attaching the pole mount to anesthesia poles using clamp parts and available arm attachments.
Steps for connecting the dental unit to a compressed air source, including tubing and pressure settings.
Instructions for connecting the dental unit to a nitrogen source, including tubing and pressure settings.
Explanation of controls like the toggle switch, volume knob, and bottle selector switch for water delivery.
Details on activating handpieces, color coding, factory preset pressures, and connecting handpieces.
Procedure for refilling the unit's water bottles without disconnecting from the air source.
Essential maintenance tasks including handpiece oiling, flushing lines, and cleaning the unit.
Instructions on how to lubricate the polisher handpiece for optimal performance.
Steps for lubricating the high-speed drill handpiece to ensure proper function.
Comparison of magnetostrictive and piezo electric scaler technologies, highlighting differences in operation and performance.
Details on standard scaling tips (#1 Universal, #2 Heavy Scaling, #10P), their use, and potentiometer operation.
Guide on adjusting water flow for piezo scalers, emphasizing minimal water usage for improved visibility.
Explains technique differences between magnetostrictive (cavitron) and piezo electric scaler tips for calculus removal.
Guidelines for using Satelec tips, tightening tips, and using tips without water ports to prevent damage.
Procedures for flushing, cleaning, and sterilizing handpieces and tubing to maintain performance.
Regular inspection and replacement of o-rings on the handpiece to ensure proper sealing and function.
Details on warranty periods for various unit parts, compressors, polishers, drills, and piezo scalers.
Troubleshooting steps for the unit when no water is supplied to the scaler or high-speed drill.
Diagnosing and resolving issues such as the prophy angle not spinning, seating improperly, or lacking power.
Troubleshooting common problems like the drill not spinning, stuck burs, ejected burs, or air leaks.
Information on standard and push-button turbines, including part numbers and available models.