If the Meter does not work while the fuse is all right, send it to
your dealer for repair.
C. Replacing the Battery (see figure 12)
To avoid false readings, which could lead to electric
shock or personal injury, replace the battery as soon as the
battery indicator “ appears.
Make sure the test leads are disconnected from the circuit
being tested before opening the case bottom.
To replace the battery:
1.
2.
3.
4.
5.
Press the POWER to turn the Meter off and remove all
connections from the terminals.
Remove the screw from the battery compartment, and
separate the battery compartment from the case bottom.
Remove the battery from the battery compartment.
Replace the battery with a new 9V battery (NEDA1604,
6F22 or 006P)
Rejoin the case bottom and battery compartment, and
reinstall the screw.
Warning
l If the Meter beeps, the fuse is good.
l If the display shows , replace the fuse and test again.
l If the display shows any other value, have the Meter serviced
and contact your dealer immediately.
(figure 12)
possible
32

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the UNI-T UT60C and is the answer not in the manual?

UNI-T UT60C Specifications

General IconGeneral
Data holdYes
Product typeDigital multimeter
Frequency range0.01 - 10000 kHz
AC current range0.4 - 10 A
AC voltage range4 - 750 V
DC voltage range0.4 - 1000 V
Temperature measurement range-40 - 1000 °C
Battery voltage9 V
Dimensions (WxDxH)85 x 177 x 40 mm
Weight and Dimensions IconWeight and Dimensions
Weight340 g