EasyManuals Logo
Home>UNI-T>Multimeter>UT71

UNI-T UT71 User Manual

UNI-T UT71
73 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #46 background imageLoading...
Page #46 background image
43
Model UT71A/B/C/D/E: OPERATING MANUAL
H. Measuring Temperature
Warning
To avoid harms to you, please do not attempt to
input voltages higher than 60V DC or 30V rms AC.
Set the rotary switch to ºC ºF, the display shows OL.
Short circuit the test leads to show the room
temperature. The Meter is default to Celsius ºC
degree unit, you can change units by press the BLUE
button once you have selected the temperature
function.
Insert the point contact temperature probe into the
Meter as figure 10.
Place the temperature probe to the object being
measured.
The measured value shows on the display after
several seconds.
1.
2.
3.
Figure 3-8. Temperature Measurement
ºC ºF
To measure temperature, set up the Meter as shown
in Figure 3-8 and proceed the following.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the UNI-T UT71 and is the answer not in the manual?

UNI-T UT71 Specifications

General IconGeneral
BrandUNI-T
ModelUT71
CategoryMultimeter
LanguageEnglish

Related product manuals