EasyManua.ls Logo

UNI EV Series - Page 20

Default Icon
21 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating and mounting manual (translation)
EV / EVF
_______________________________________________________________________________________________________
220.100.091-05 Page 20 /21 Version: 06/2017
TM 4474
Flange
version
Fig.2 5/10/25/40-EV 5/7/10N
Spare part kit, Solenoid drive (800)
Fig.3 5/10/25/40-EVF 5/7/10N Spare part kit, Solenoid drive (800)
Fig.4 5/10/25/40-EVF 5/7/10N
Spare part kit, metal-of-metal sealing
Solenoid drive (800)
Fig.5 100-EVF..N.. (DN25) Solenoid drive (800)
Fig.6 40-EVF..NH.. (DN15, DN25) Solenoid drive (800)
Dimension with standard solenoid drive
Connection G Dimension
1/2
(5)
3/4
(7)
1
(10)
1 1/4
(12)
1 1/2
(15)
2
(20)
Installation length A
95 95 - - - -
100-EVF.... B
572 572 - - - -
B`
722 722 - - - -
ØC
194 194 - - - -
D
111 111 - - - -
Flange DN Dimension 15
(5N)
20
(7N)
25
(10N)
32
(12N)
40
(15N)
50
(20N)
Installation length A (*)
130 150 160 180 200 230
Flange ANSI Dimension 1/2" 3/4" 1” 11/4” 11/2” 2”
5-EV..NÜ..92/93 B
447 447 447 478 478 488
B`
565 565 578 628 628 638
ØC
153 153 153 194 194 194
10-EV..NÜ..92/93 B
447 447 470 478 478 -
B`
578 578 620 628 628 -
ØC
153 153 194 194 194 -
25-EV..NÜ..92/93 B
447 447 470 478 478 -
B`
578 578 620 628 628 -
ØC
153 153 194 194 194 -
40-EV..NÜ..92/93 B
470 470 470 511 - -
B`
620 620 620 691 - -
ØC
194 194 194 230 - -
5-EVF..NÜ..92/93 B
466 466 466 498 498 508
B`
583 583 597 648 648 658
ØC
153 153 153 194 194 194
10-EVF..NÜ..92/93 B
466 466 490 498 498 -
B`
597 597 640 648 648 -
ØC
153 153 194 194 194 -
25-EVF..NÜ..92/93 B
466 466 490 498 498 -
B`
597 597 640 648 648 -
ØC
153 153 194 194 194 -
40-EVF..NÜ..92/93 B
490 490 490 531 - -
B`
640 640 640 711 - -
ØC
194 194 194 230 - -
40-EVF…NH.Ü…. B
583 583 583 - - -
B`
740 740 740 - - -
ØC
194 194 194 - - -
Flange DN
Flange ANSI
Dimension 15
(5N)
1/2
20
(7N)
3/4
25
(10N)
1
32
(12N)
1 1/4
40
(15N)
1 1/2
50
(20N)
2
Installation length A
- - 230(#) - - -
100-EVF…N.. B
- - 629 - - -
B`
- - 779 - - -
ØC
- - 194 - - -
D
- - 189 - - -
(#) VG-chamber PN100
A = Dimension at DIN (resp. flanges ANSI and dimension DIN or flanges and dimension at DIN)
(*) = Dimension at ANSI 150lbs (see data sheet on our website armature installation lenght
225 100 026)
B` = Dimension for removing the solenoid drive