K
EYBOARD
I
NTER
S
CAN
C
ODE
D
ELAYS
³816580
* InterScan Code Delay 800 msec - The time
specified represents the amount of time between
individual 11 bit-scan codes. This parameter may
need to be adjusted for operation with certain PC
keyboard BIOS.
³8165750
InterScan Code Delay 7.5 msec - This time
specified represents the amount of time between
individual 9 bit-scan codes. This parameter may
need to be adjusted for operation with certain PC
keyboard BIOS.
³81651500
InterScan Code Delay 15 msec - The time
specified represents the amount of time between
individual 11 bit-scan codes. This parameter may
need to be adjusted for operation with certain PC
keyboard BIOS.
³916500
~
ariable InterScan Code Delay msec - Refer to
Multi-Code Method on page 2. Sets value in 100
microsecond increments.
C
ONTROL
S
ETS
In general, standard bar code symbologies will only encode the ASCII character
set. Function keys, arrow keys and many other extended keys on an IBM
compatible keyboard do not translate to ASCII characters. One method of ‘bar
coding’ the extended keys is to substitute the extended key codes when a
specific ASCII control character is found in the bar code stream. The Control
Sets are specific translations of the ASCII (HEX) set.
Control Set #1
³416484
Enable Control Set #1
³416404
* Disable Control Set #1
69