85
e. Spray compressed air in the connector area by pointing the
tube/nozzle about 1/2 inch away from t the surface. (Caution: When
using compressed air, always wear eye protection, do riot point nozzle
at yourself and others make sure the nozzle or tube is pointing away
from your face: and read warning label on compressed air product.)
f. Remove any lint left by the cotton-tipped applicator.
g. If grease and other dirt are found on other areas of the cradle, use a
lint free cloth and isopropyl alcohol to remove.
h. Allow at least 10 to 30 minutes (depending on ambient temperature
and humidity) for the isopropyl alcohol to air dry before applying power
to cradle.
Note on drying time: If the temperature is low and humidity is high, longer drying
time is required. Warm temperature and dry humidity require less drying time.