-38- © 2019 unitech Electronics Co., Ltd. All rights reserved.
unitech is a registered trademark of unitech Electronics Co., Ltd.
MS851 User’s Manual
Table 3-1 Reading Standard Code 128 & GS1-128
Standard Code 128 GS1-128 Effect and Example
Disable Disable No Code 128 symbols can be read.
Disable Enable Read only symbols with leading FNC 1.
Examples:
FNC1
ABCD
FNC1
E are read as ABCD
29
E
A
FNC1
BCD
FNC1
E are read as ABCD
29
E
FNC1FNC1
ABCD
FNC1
E are read as ABCD
29
E
ABCD
FNC1
E cannot be read
ABCDE cannot be read
Enable Disable Read only symbols without leading FNC 1.
Examples:
FNC1
ABCD
FNC1
E cannot be read
A
FNC1
BCD
FNC1
E cannot be read
FNC1FNC1
ABCD
FNC1
E cannot be read
ABCD
FNC1
E is read as ABCD
29
E
ABCDE is read as ABCDE
Enable Enable Read both types of symbols.
Examples:
FNC1
ABCD
FNC1
E are read as ABCD
29
E
A
FNC1
BCD
FNC1
E are read as ABCD
29
E
FNC1FNC1
ABCD
FNC1
E are read as ABCD
29
E
ABCD
FNC1
E is read as ABCD
29
E
ABCDE is read as ABCDE