UMI-B1 UL Series Inverter Function parameters
77
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
frequency
changing
ratio
P08.47
Action
selection
at power
loss
0x0000x111
LED ones: Action selection when power off.
0: Save when power off
1: Clear when power off
LED tens: Action selection when MODBUS
set frequency off
0: Save when power off
1: Clear when power off
LED hundreds:The action selection when
other frequency set frequency off
0: Save when power off
1: Clear when power off
0x000
P08.48
Most
significant
digit of
original
power
consumpti
on
This parameter is used to set the original
value of the power consumption.
The original value of the power consumption
=P08.48 x 1000 + P08.49
Setting range of P08.48: 059999 kWh (k)
Setting range of P08.49:0.0999.9 kWh
0 kWh
P08.49
Least
significant
digit of
original
power
consumpti
on
0.0 kWh
P08.50
Magnetic
flux
braking
This function code is used to enable magnetic
flux.
0: Invalid.
100150: the bigger the coefficient, the
bigger the braking strength.
This inverter can slow down the motor by
increasing the magnetic flux. The energy
generated by the motor during braking can be
transformed into heat energy by increasing
the magnetic flux.
0