UMI-B1 UL Series Inverter Function parameters
76
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
1: Valid for all frequency setting manner
2: Invalid for multi-step speed when
multi-step speed has the priority
LED hundreds: action selection during
stopping
0: Setting is valid
1: Valid during running, cleared after stopping
2: Valid during running, cleared after
receiving the stop command
LED thousands: / keys and analog
potentiometer integral function
0: The Integral function is valid
1: The Integral function is invalid
P08.43
Integral
ratio of the
keypad
potentiome
ter
0.0110.00s
0.10s
P08.44
UP/DOWN
terminals
control
setting
0x000x221
LED ones: frequency control selection
0: UP/DOWN terminals setting valid
1: UP/DOWN terminals setting valid
LED tens: frequency control selection
0: Only valid when P00.06=0 or P00.07=0
1: All frequency means are valid
2: When the multi-step are priority, it is invalid
to the multi-step
LED hundreds: action selection when stop
0: Setting valid
1: Valid in the running, clear after stop
2: Valid in the running, clear after receiving
the stop commands
0x000
P08.45
UP
terminals
frequency
changing
ratio
0.0150.00s
0.50 s
P08.46
DOWN
terminals
0.0150.00s
0.50 s