UMI-B1 UL Series Inverter Function parameters
75
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
Setting range: 200.02000.0V
In order to prevent customers set the value is
too large, it is recommended setting range:
Voltage
220V
460V
Range
375400V
715780V
P08.39
Cooling
fan running
mode
0: Rated running mode
1: The fan keeps on running after power on
0
P08.40
PWM
selection
0x000x21
LED ones: PWM mode selection
0: PWM mode 1, three-phase modulation and
two-modulation
1: PWM mode 2, three-phase modulation
LED tens: low-speed carrier frequency limit
mode
0: Low-speed carrier frequency limit mode 1,
the carrier frequency will limit to 2k if it
exceeds 2k at low speed
1: Low-speed carrier frequency limit mode 2,
the carrier frequency will limit to 4k if it
exceeds 4k at low speed
2: No limit
0x01
P08.41
Over
commissio
n selection
LED ones
0: Invalid
1: Valid
LED tens (for factory commissioning)
0: Light overcommission; in zone 1
1: Heavy overcommission; in zone 2
0x00
P08.42
Keypad
data
control
setting
0x00000x1223
LED ones: frequency enable selection
0: Both / keys and analog potentiometer
adjustments are valid
1: Only / keys adjustment is valid
2: Only analog potentiometer adjustments is
valid
3: Neither / keys nor digital
potentiometer adjustments are valid
LED tens: frequency control selection
0: Only valid when P00.06=0 or P00.07=0
0x0000