16. Hidden Menu (Series 5)
Control Board
• Control Board hidden Menu
parameters
- At the display button, option
10-FrU Control Board
- Last Control Board Firmware
Version 3118
52
DISPLAY DESCRIPTION RANGE PARAMETER DEFAULT
FrU
Firmware version
// //
//
CD1
Card code
PE1740 PE1740 PE1740
CD2
Card version
A0 / Z9 //
//
OV
Setting Master-Slave
OV1 Master Oven
OV
OV2 Slave 1 Oven
OV3 Slave 2 Oven
OV4 Slave 3 Oven
DEG
Celsious or fahrenheit
Degrees
CEL
Set the degrees in Celsius
CEL
FAR
Set the degrees in Fahrenheit
STB Stand by oven
ON Stand by oven after 15 minutes that is not used
ON
OFF
Oven is always on. Enter in stand by mode when pressed START/STOP
for 6 sec.
LMP Cooking chamber light
ON Oven lights always on
ON
OFF Lights turn off after 15 sec.
LOC
Locking of the first 20
stored programmes
OFF Allow to change any program stored by the user
OFF
ON Locking of the first 20 stored programs by the user
SHI
Length of rinse aid cycle
0
Rinse aid standard quantity
0
1
Twice rinse aid standard quantity
2
Triple rinse aid standard quantity
HID
Hiding parameters of
Chef Unox preset recipes
ON Hiding cooking parameters of Unox preset recipes
ON
OFF
Allow to view and modify the cooking parameters of Unox preset
recipes
PRG
Allow just the use of
programs
OFF Allow to use the oven in manual mode and with programs
OFF
ON Use the oven just with the programs
GN
Settings of oven: bakery
or gastronomy
1
Gastronomy oven settings: Activate the Gastronomy + Bakery's
programs and functions
1
0
Bakery oven settings: Activate the Bakery's programs and functions
BUZ
External Buzzer
0 Utilization of control board buzzer for end cooking
0
1 Utilization of power board buzzer for end cooking
STE
Internal chamber
temperature visualization
ON
Visualization of the set internal temperature chamber and the internal
measured temperature chamber each 4"
ON
OFF
Visualization of the set internal temperature chamber. To view the
internal measured temperature chamber press 2 times the button "-"
and keep it pressed
EPW Efficient Power settings
MIN ↓ Consumption - ↔ Performance
MAXMED ↔ Consumption - ↔ Performance
MAX ↑ Consumption - ↑ Performance
FOB
Buzzer working frequency 0 / 4000 //
4000
TAL
Time switching on
chamber light
0 / 9999
Choose the time to the chamber lights enter in stand by mode (in
seconds)
15
1 0
F
r
U
3 1 1 8