1. Breakdown Messages (Series 4)
BLAST CHILLER – HOLDING CABINET
- Blast Chiller
- Holding Cabinet
Breakdown messages of blast chiller
Breakdown messages of holding cabinet
60
ERROR DESCRIPTION EFFECT POSSIBLE CAUSES SOLUTION
The connection wires of the cavity probe
are disconnected from the power card
Check the electrical circuit connection
Damaged chamber probe Check and eventually replace the probe
Damaged blast chiller power card Replace power card
The connection wires of the chamber
probe are disconnected from the power
card
Check the electrical circuit connection
Damaged core probe Check and eventually replace the probe
Damaged blast chiller power card Replace power card
Overpressure in the refrigeration circuit
Switch off the power supply of the blast
chiller, wait for some minutes and then
switch on again. If remains the letter
EA3 check the refrigeration circuit
Damaged blast chiller power card Replace power card
EA4
Filter cleaning
Don't change the normal
work of blast chiller but it will
always remain the message
EA4 for 3”
Filters working limit reached Clean or replace the filter
Oven / blast chiller connecting cable is
damaged or disconnected
Check and eventually replace the
connecting cable
Damaged blast chiller power card Replace power card
EA1
Break down
system of electric
circuit of the
chamber probe
The blast chiller stops and
it's not possible to restart
(remains the letters EA1)
EA2
Break down
system of electric
circuit of the
chamber core
probe
Impossible to set heart
temperature and use the
programmes that use the
core probe
EA3
Overpressure
The blast chiller stops and
it's impossible to restart
(remains the letters EA3)
EA5
Loss of
communication
between oven and
blast chiller
The blast chiller stops and
it's impossible to restart
ERROR DESCRIPTION EFFECT POSSIBLE CAUSES SOLUTION
The connection wires of the cavity probe
are disconnected from the power card
Check the electrical circuit connection
Damaged chamber probe Check and eventually replace the probe
Damaged holding cabinet power card Replace power card
The connection wires of the humidity
probe are disconnected from the power
card
Check the electrical circuit connection
Damaged humidity probe Check and eventually replace the probe
Damaged holding cabinet power card Replace power card
Oven / holding cabinet connecting cable
is damaged or disconnected
Check and eventually replace the
connecting cable
Damaged holding cabinet power card Replace power card
EL1
Break down
system of electric
circuit of the
chamber probe
The holding cabinet stops
and it's not possible to
restart
EL2
Break down
system of electric
circuit of the
chamber humidity
probe
The temperature control
keeping to work, the water
eletrovalve and the
resistence are deactivate
EL3
Loss of
communication
between oven and
holding cabinet
The holding cabinet stops
and it's not possible to
restart