EasyManuals Logo

Uponor Smatrix Base Pro Quick Guides

Uponor Smatrix Base Pro
10 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
Register multiple controllers
Up to 16 controllers can be registered to an interface.
All additional controllers in the system must be
registered to the interface.
NOTE!
At least one thermostat must be registered to
the additional controller before registering to
the interface.
See steps 16 and 17 in the “Register thermostat and/
or system device to a controller” section for more
information.
Unregister one channel or system device
When a channel or system device is inaccurately
registered or if a thermostat registration needs to be
redone, it is possible to remove the current registration
from the controller.
NOTE!
The controller must be unregistered in the
interface as well. Go to menu Main menu >
Preferences > Link and unregister.
To unregister a channel:
1. Enter registration mode. Channel 1 LED flashes red/
green, or the first unregistered channel flashes red.
2. If a system device (timer etc) is to be unregistered,
enter system channel registration mode. The power
LED flashes according to the pattern long blink,
short pause, long blink and channel 1 LED flashes
red/green.
3. Use buttons < or > to move the pointer (LED
flashes red) to the selected channel (flashes green if
registered) to unregister.
4. Press the < and > buttons simultaneously for about
5 seconds until the LED for the selected channel
starts flashing red.
Unregister all channels
When one or more channels are inaccurately registered,
it is possible to remove all registrations at the same
time.
NOTE!
The controller must be unregistered in the
interface as well. Go to menu Main menu >
Preferences > Link and unregister.
To cancel all channel registrations:
1. Enter registration mode. Channel 1 LED flashes red/
green, or the first unregistered channel flashes red.
2. Press the < and > buttons simultaneously for about
10 seconds until the LEDs for all channels except
one turn off. The one remaining flashes red.
Room bypass
To reach the bypass settings, the controller must be
registered to the interface.
1. In the interface, go to the Room bypass menu,
Main menu > System settings > Room bypass.
2. Select a controller.
3. Select up to a maximum of two rooms.
4. Press the Confirm button to save and exit the
menu.
Communications protocol
The system is based on a bus communications protocol
(requires the thermostats unique ID to be registered
to the controller), utilising daisy chain, direct or
star topology connections. This allows serial and
parallel connections, makes wiring and connection
of thermostats and system devices much easier than
connecting one thermostat per connection terminal.
The wide array of connection possibilities presented
with this communications protocol can be combined in
any way best suited for the current system.
Other functions
See full manual for more information about
Autobalancing of actuators (eliminating the need
of manual balancing,on by default), Heat pump
integration, Cooling, Comfort/ECO settings, KNX
module, Room check, and Supply check etc.
QUICK GUIDE
8
UPONOR SMATRIX BASE PRO · QUICK GUIDE
EN
CZ
DE
DK
EE
ES
FI
FR
HR
HU
IT
LT
LV
NL
NO
PL
PT
RO
RU
SE
SI
SK

Other manuals for Uponor Smatrix Base Pro

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Uponor Smatrix Base Pro and is the answer not in the manual?

Uponor Smatrix Base Pro Specifications

General IconGeneral
BrandUponor
ModelSmatrix Base Pro
CategoryController
LanguageEnglish

Related product manuals