32
Uponor Climate Co˘ntrol™ Zoning System Installation Guide
33
Section 9
Technical Data
General
IP: IP30 (IP: degree of non-accessibility to the active
parts of the product and degree of non-accessibility
of water)
Max. ambient relative humidity (RH): 95% max. at
68°F/20°C.
• Class II low-voltage device
Thermostat T-75
• Certication
- FCC Part 15 Subpart C
- Industry Canada Category I device
• Approval and certication:
- KNX: Konnex approval and certication
• Power supply: 2x Alkaline AAA 1.5V
• Voltage: 2.2V to 3.6V
• Operating temperature: 32°F/0°C to 113°F/45°C
• Storage temperature: 14°F/-10°C to 149°F/65°C
• Radio frequency: 902-928 MHz
Transmitter duty cycle: 1%
Interface I-75
• CE marking:
- Low-voltage tests: EN 60730-1 and EN
60730-2-1
- EMC tests: EN 60730-1
• Power supply: 11VDC ±10% from controller
• Operating temperature: 32°F/0°C to 131°F/55°C
• Storage temperature: -4°F/-20°C to 158°F/70°C
• Consumption: 1W maximum
Antenna T55
• Power supply: 11VDC ±10% from controller
• Consumption: << 1W
• Radio frequency: 902 to 928 MHz
Transmitter duty cycle: 1%
• Receiver Class: 2
Base Unit C-55
• Certication
- FCC Part 15 Subpart C
- Industry Canada Category I device
• Certication
- ICES-003
Power supply: 90-130VAC, 60Hz Class II switching
power supply
• Operating temperature: 32°F/0°C to 131°F/55°C
• Storage temperature: -4°F/-20°C to 158°F/70°C
• Consumption: 70 W in full load max at 24VAC
Demand contact: 24VAC at 2 Amps max (not fused)
Valve outputs: 24VDC ±10%, 436 mA max. per
output 1 and 2 24VDC ±10%, 218 mA max. per
output 3 to 12
Supply connection: terminal strip (push type)
polarity sensitive
* Do not substitute the external power supply. Damage to the controller
and hazardous conditions may occur. Warranty will be voided.
Use of Quick Connectors:
1. Without turning, use a thin screwdriver to press
the white button of the terminal to insert or
remove a wire.
2. Insert a wire in the quick connector.
3. Release the white button.
4. Run the cable in the cable guides secure it.
5. Screw clamp to secure the cable
of antenna or/and extension.
Exercise Actuators and Pumps
This exercise maintains the functionality of the
actuators and pumps. A ve-minute activation
is scheduled every week.
Cancel Exercise
1. Uponor screen
> Main Menu > Settings > System
Parameters
> Valve/Pump Exercise > Cancel Exercise
2.
> Press OK.
Exercise Valve and Pump
1. Uponor screen
> Main Menu > Settings > System
Parameters
> Valve/Pump Exercise > Exercise Valve
and Pump
2. Set the time and date for the
ve-minute activation.
> Press OK.
Exercise Actuator Only
1. Uponor screen
> Main Menu > Settings > System
Parameters
> Valve/Pump Exercise > Exercise
Valve Only
2. Set the time and date for the ve-
minute activation.
> Press OK.
Temperature Unit
1. Uponor screen > Main Menu >
Settings
> System Parameters >
Temperature Unit
2.
>°C or °F
> Press OK.
Backlight
1. Uponor screen > Main Menu >
Settings
> System Parameters >
Backlight
2. Select:
Always ON
Dimmed (when inactive): reduced screen brightness
OFF (when inactive): backlighting off
> Press OK.
Installer Level
The device has another mode: the Installer
level. Only the installer should set these
settings.
The Installer access level provides additional access to:
The information menu
All advanced level parameters
• Pump management settings
• Base unit identication
• Language
Vacation Mode
Vacation mode allows the user to easily set a temperature
reduction common to all rooms. The thermostat settings
are ignored during this period. The symbol
on the
Uponor screen indicates that the system is in
Vacation mode.
The reduce vacation setpoint applies
throughout the installation for all installed
room thermostats. The setting range is
41°F to 95°F.
The minimum and maximum limitations have
priority over the Vacation mode reduction.
For example if the minimum and maximum
temperature range of a room is set to 68°F
to 77°F, and the holiday temperature is set
to 59°F for all rooms, the temperature for
this room will not drop below 68°F.
Applying the Vacation Mode
1. Uponor screen > Main Menu > Vacation Mode >
Apply Vacation Mode
2. Enter time and date for the start
of the vacation period
> Press OK.
3. Enter time and date for the end
of the vacation period
> Press OK.
4. Enter the Vacation temperature
setpoint > Press OK.
Example: Vacation Mode can be cancelled before the
date is entered into the system.
Cancelling the Vacation Mode
1. Uponor screen > Main Menu > Vacation Mode >
Cancel Vacation Mode
2. Select Yes > Press OK.
Exercise Valve and Pump
Exercise Valve Only
Cancel Exercise
Exercise Setup
Monday
1 : 00
Exercise Time
Monday
1 : 00
Exercise Time
Please choose the
required temp unit.
˚C
˚F
Temperature Unit
Dimmed (when inactive)
OFF (when inactive)
Always ON
Backlight
14 Jan 2008
2 : 02
Set Date/Time
15 Jun 2008
2 : 02
End Date
59˚F
Vacation Te mperature
Cancel Vacation
Mode?
Ye s
No
Cancel Vacation Mode