Uponor Climate Co˘ntrol™ Zoning System Installation Guide
9
Resetting the Base Unit
Resetting the base unit will cancel all channel
registrations, allowing the user to change all
the registrations.
1. Press the Test button for 10 seconds.
2. The Test LED ashes for at least two seconds,
then all LEDs will turn off (except the power LED).
All parameters are erased.
3. New installation and registration after reset
is necessary.
Installation Example
Thermostat/Zone #01 controls two actuators
connected to channels 1a and 1b.
Channel 2a and 2b are not used in this diagram.
Thermostat/Zone #02 controls two actuators
connected to channels 3 and 4.
Thermostat/Zone #03 controls one actuator
connected to channel 5.
Thermostat/Zone #04 controls one actuator
connected to channel 6.
Thermostat/Zone #10 controls three actuators
connected to channels 10, 11 and 12.
Warning: Disconnect the power before
installing or changing the device wiring.
Powering the Base Unit
Check the actuators and antenna to
ensure that the wiring is complete.
Check that the power compartment
lid is closed.
Connect the power
supply plug into the
electrical outlet.
Zones
Channels
Mounting the Base Unit
Position the base unit just above the manifold.
Ensure the power receptacle is within reach of
the base unit's power supply cord.
Check that the base units cover can be
removed easily.
Check that the connectors and switches are
easily accessible.
Caution: Mount the base unit horizontally.
There is a risk for overheating if the base unit is
mounted vertically or on a at surface.
1. Hold base unit to wall; mark mounting hole locations
on the wall with a pencil.
2. Drill the wall.
3. Press the anchor into the hole.
4. Attach the base unit to the wall with screws.
Information: Each thermostat can control any
number of channels. Installation and
maintenance are simplied if actuators
controlled by the same thermostat are wired to
channels in sequence.