query current value of parameter:
AT+SOCKA{CR} or AT+SOCKA?{CR}
{CR}{LF}+SOCKA:protocol,address,port{CR}{LF}{CR}{LF}OK{CR}{LF}
set parameter:
AT+SOCKA=protocol,address,port{CR}
{CR}{LF}OK{CR}{LF}
parameter :
protocol : communication protocol
“TCP” : TCP
“UDP : UDP
address : server address, IP or domain name
port : server port, 1~65535
4.2.1.26. AT+SOCKB
function : query/set socket B parameters.
format :
query parameter introductions:
AT+SOCKB=?{CR}
{CR}{LF}+SOCKB:<"TCP","UDP">,<"address">,<port>{CR}{LF}{CR}{LF}OK{CR}{LF}
query current value of parameter:
AT+SOCKB{CR} or AT+SOCKB?{CR}
{CR}{LF}+SOCKB:protocol,address,port{CR}{LF}{CR}{LF}OK{CR}{LF}
set parameter:
AT+SOCKB=protocol,address,port{CR}
{CR}{LF}OK{CR}{LF}
parameter :
protocol : communication protocol
“TCP” : TCP
“UDP : UDP
address : server address, IP or domain name
port : server port, 1~65535
4.2.1.27. AT+SOCKAEN
function : query/set enable/disable socket A.
format :
query parameter introductions:
AT+SOCKAEN=?{CR}
{CR}{LF}+SOCKAEN:<"on","off">{CR}{LF}{CR}{LF}OK{CR}{LF}
query current value of parameter:
AT+SOCKAEN{CR} or AT+SOCKAEN?{CR}