7 Remove the developing units. 8 Remove the right cover and the >HIGH VOLTAGE PWB<.
9 Check the resistor from the drum contacts.
10 Resistor > 1 Ohm set the correct position of the drum springs.
HIGH VOLTAGE PWB
Figure right side
Figure inner side
CYAN
BLACK
MAGENTA
YELLOW
right side
inner side
The resistor between the contact springs
(red) must be < 1 Ohm.
wrong
OK