SCUBAPRO S600-S550 SECOND STAGES
ļ2003 SCUBAPRO
Important note
: The following information is not designed to be a complete training guide for servicing the listed SCUBAPRO regulators. All SCUBAPRO
technicians are required to attend an annual service training program to insure safe handling and servicing of SCUBAPRO products. All SCUBAPRO technicians
must be employed by an authorized SCUBAPRO facility.
4
P
/
N
4
3
0
4
0
0
0
0
TOOLS
NEEDED
No tools needed
this step
Remove the two-piece cover, friction
washers and diaphragm from the
second stage housing.
Remove the stop clip from the knob.
Configuration B: Turn the cracking
effort adjustment knob inward a few
turns for easier stop clip removal.
Remove the stop clip from the plug.