SCUBAPRO X650 SECOND STAGE
©2003 SCUBAPRO
Important note: The following information is not designed to be a complete training guide for servicing the listed SCUBAPRO regulators. All SCUBAPRO
technicians are required to attend an annual service training program to insure safe handling and servicing of SCUBAPRO products. All SCUBAPRO technicians
must be employed by an authorized SCUBAPRO facility.
6
P
/
N
4
3
0
4
0
0
0
0
TOOLS
NEEDED
No tools needed
this step
Push the adjustment components out
of the dive switch as shown.
Remove the o’ring.
P
/
N
4
3
0
4
0
0
0
0
TOOLS
NEEDED
No tools needed
this step
To remove the knob stem, use the
knob.
Hold the sleeve and screw the knob
clockwise.
Remove the o’ring.
Use the small screwdriver to thread the
adjustment screw clockwise. Carefully
remove the screw.
Remove the o’ring as shown.