EasyManua.ls Logo

Uwatec MK 11 - User Manual

Uwatec MK 11
200 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
SCUBAPRO REGULATORS MANUAL
Congratulations on purchasing a SCUBAPRO regulator and welcome to SCUBAPRO.
We are confi dent that you will enjoy extraordinary performance from our regulator,
designed and manufactured using the most advanced technology.
We thank you for choosing SCUBAPRO and wish you a future of safe dives and
underwater enjoyment!
TABLE OF CONTENTS
1. Important Warnings 2
2. CE Certifi cation 2
2.1 EN 250: 2000 norm regulations and what they mean 2
2.2 Defi nition of ‘SCUBA’ according to EN 250: 2000 2
2.3 Limitations provided by EN 250: 2000 2
3. Important warning reminders 3
4. Regulator system 3
4.1 First stage 4
4.2 Second stage 4
5. Technical features 4
5.1 First Stages 5
5.2 Second Stages 6
5.3 First and second stage features 7
6. Preparing for use 9
6.1 Set-up/in-use warning 9
7. Equipment use 10
7.1 Second stages with Venturi effect (V.I.V.A.) adjustment 10
7.2 Cold water use 11
7.3 Post dive 11
8. Equipment care and maintenance 12
8.1 Care 12
8.2 Maintenance 13
9. Nitrox 13
9.1 Main features of Nitrox dedicated regulators 14
9.2 Use and maintenance notes 14
10. Troubleshooting 15
English

Table of Contents

Questions and Answers

  • M
    Madison WoodAug 7, 2025
    What to do if Uwatec MK 11 regulator free flows?
    • R
      Ruben WebbAug 7, 2025
      If the regulator free flows, it might be due to the Venturi effect. To address this, try covering the mouthpiece with a finger, directing the mouthpiece opening downwards, or submerging it.
  • E
    Eric StricklandAug 12, 2025
    What to do if Uwatec Diving Instrument continues to free flow?
    • D
      donald86Aug 12, 2025
      If the free flow continues, it indicates a malfunctioning regulator. In this case, do not begin or end the dive and have the regulator checked by an authorized technician.
  • I
    ianchenAug 16, 2025
    What to do if Uwatec Diving Instrument pressure gauge shows zero?
    • M
      Michael GrahamAug 16, 2025
      If the pressure gauge shows zero after opening the cylinder valve, here are a few possible causes: 1. The cylinder might be empty. In this case, fill the cylinder. 2. The pressure gauge might be malfunctioning. In this case, have the pressure gauge replaced by an authorized technician. 3. The cylinder valve might be malfunctioning. In this case, have the cylinder valve checked by an authorized technician.
  • J
    Jennifer SchroederAug 20, 2025
    Why is there a water leak inside my Uwatec MK 11 Diving Instrument regulator second stage?
    • J
      Joshua GarciaAug 20, 2025
      A water leak inside the regulator second stage of your Uwatec Diving Instrument could be due to dirt, a malfunctioning exhaust valve, or damage to the mouthpiece or diaphragm. Have the regulator checked by an authorized technician.
  • D
    Dana GrahamAug 25, 2025
    What to do if Uwatec MK 11 has no air supply?
    • J
      Jamie JenkinsAug 26, 2025
      If there is no air supply from your Uwatec Diving Instrument, it could be due to a malfunctioning regulator (either the first or second stage). Have the regulator checked by an authorized technician.
  • N
    nathanielyoungAug 28, 2025
    What causes HP or IP leak in Uwatec MK 11 Diving Instrument?
    • R
      Ronnie TaylorAug 28, 2025
      An HP or IP leak in your Uwatec Diving Instrument is caused by damaged O-rings. Have the O-rings replaced by an authorized technician and avoid overtightening the connections.
  • T
    Tyler AllenSep 2, 2025
    Why is there a valve leak in Uwatec MK 11 Diving Instrument?
    • C
      chelsea64Sep 2, 2025
      A valve leak in your Uwatec Diving Instrument is caused by a defective valve or stem. Have the valve checked by an authorized technician.

Uwatec MK 11 Specifications

General IconGeneral
TypeDive Computer
DisplayLCD
Nitrox compatibilityYes
Water ActivationYes
LogbookYes
Audible AlarmsYes
Battery LifeApprox. 300 dives

Related product manuals