4.2.2 Select Auto Power Off Setting
The scale is equipped with Auto Power Off Function. The
scale will power off automatically if it is not used
for 4 minutes. Follow the below steps to enable/disable
Auto Power Off Function.
a. Scale is off
b. Press and hold TARE, then press ON/ZERO
c. Scale displays F.1
d. Press TARE three times
e. Scale displays F.4
f. Press MODE to shift between 0._OFF and 4._OFF
-To enable Auto Power Off Function, press TARE when
4._OFF appears
-To disable Auto Power Off Function, press TARE when
0._OFF appears
g. Press ON/ZERO to restart the scale or TARE for next
function setup
4.2.3 Select RS-232 Baud Rate & Protocol
This scale is equipped with 4 RS232C output baud rate
and 2 transmission protocol settings for user to select.
a. Scale is off
b. Press and hold TARE, then press ON/ZERO
c. Scale displays F.1