Details the type and height of the display used in the weighing indicator.
Specifies the maximum number of counts the display can show.
Lists the available graduation values for the indicator.
Defines the minimum input voltage required per display resolution.
Indicates the range for zero point adjustment.
States the non-linearity percentage of the indicator.
Identifies the type of Analog-to-Digital converter used.
Specifies the bit resolution of the A/D converter.
States the speed of the A/D conversion process.
Defines the maximum input voltage the indicator can handle.
Details the excitation voltage for load cells and connection capacity.
Specifies the zero drift over temperature.
Specifies the span drift over temperature.
Details the power source requirements and consumption.
States the acceptable range of operating temperatures.
Indicates the operational range of the indicator.
Specifies the maximum operating humidity.
States the net weight of the indicator.
Provides the physical dimensions of the indicator.
Illustrates the front panel of the weighing indicator, showing buttons and indicators.
Explains the meaning of various signals displayed by the indicator like POWER, TARE, ZERO, GROSS, NET, MOTION.
Details the functions of front panel keys such as ZERO, TARE, GROSS/NET, and PRINT.
Describes front panel control keys: SET, S=, SM, STANDBY/OPERATE.
Details AC power, printer, external display, load cell, and RS-232 interfaces on the back panel.
Details the wiring diagram for connecting a load cell signal cable.
Explains the pin assignment for the RS-232 serial communication interface.
Explains the pin assignment for the Centronics parallel printer interface.
Explains the pin assignment for the 4-pin external display interface.
Guides on how to access and set various functions of the indicator.
Function to display internal A/D resolution.
Key testing function to verify button operations and their corresponding numbers.
Performs a check to see if all segments of the VFD light up.
Allows setting the RS-232 baud rate from various available options.
Configures transmission protocol parameters: parity, data bit, and stop bit.
Sets the RS-232 transmission mode: Stream, Auto, or Manual.
Allows selection of weight units: Kilogram, Gram, Metric ton, or Pound.
Configures the RS-232 transmission data format, including headers and weighing results.
Tests data transmission status of RS-232 and printer by pressing PRINT.
Guides on setting or changing the password for function access.
Sets the auto zero tracking range or disables it.
Sets the maximum capacity and full capacity of the weighing indicator.
Configures the division graduation based on the set capacity.
Sets the number of decimal places for displayed values.
Configures the auto zero tracking range and time intervals.
Sets the division range for motion detection stability.
Sets motion detection stability based on 3 divisions change.
Sets motion detection stability based on 1 division change.
Introduces the zero point calibration process using CAL.-0.
Procedure for entering the reference weight for span calibration.
Detailed steps for performing zero point calibration.
Detailed steps for performing span calibration with a known mass.
Troubleshooting common issues during zero calibration.
Troubleshooting common issues during span calibration.
Troubleshooting specific error 'AAAAAAA' during zero calibration.
Troubleshooting specific error 'UUUUUUU' during zero calibration.
Troubleshooting specific error 'LLLLLLL' during span calibration.
Troubleshooting specific error 'CCCCCCC' during span calibration.
Addressing issues with inadequate load cell signal for span calibration.
Troubleshooting high input signals or damaged load cells.