FUNCTION CHART
46
GB
FUNCTION TABLE PD2
47
N. DISPLAY DATAS DESCRIPTION DEFAULT
DATAS
MEMO
DATAS
0 dEF no/Si Load V2 standard datas no
1 t.AP 0 - 120 s Opening time 22.5
2 t.APP 0 - t.AP1 Opening time of pedestrian gate 6.0
3 t.Ch 0 - 120 s Closing time 23.5
4 t.ChP 0 - t.Ch1 Closing time of pedestrian gate 7.0
5 t.PrE 0 - 120 s Pre-flashing time 1.0
6 Pot. 30 to 100% Motor power 40
7 SPUn no/Si Start off Si
8 St.AP
no
ChiU
PAUS
Start in opening
- START command is not available
- command close the gate
- stop the gate and goes in Pause
PAUS
9 St.Ch
Stop
APEr
Start in closing
- command START stop the gate
- command START open the gate
StoP
10 St.PA
no
chiU
Start in pause
- START command is not available
- START command closes the gate
ChiU
11 SP.AP
no
ChiU
PAUS
Pedestrian in opening
- P START command is not available
- P START closes the gate
- gate goes in pause
PAUS
12 Ft.PA
rPAU
t.PCh
Photocell in pause
- Pause time recharged
- gate stop for a time to be set
between 0 to 120 seconds
r.PAU
GB