the display appears:
Press the MENU key to confirm, one of the
following will appear on the display:
no further corrections to carry out: do
not quit the programming
Si end of programming
Press the UP or DOWN keys to select the
wished function.
Press the MENU key to confirm.
If the function is no, on the display will
appear: FinE.
By pressing UP or DOWN you can scroll the
menus to make modifications.
If the function is Si, on the display will appear
the control panel.
The inserted data have been memorized: the
control unit is ready to be used.
INSTRUCTIONS FOR
THE INSTALLATION
The installer must provide for a device (es.
magnetotermical switch) ensuring the
omnipolar sectioning of the
PD2 equipment from the power
supply.
The standards require a separation of the
contacts of at least 3 mm in each pole (CEI
EN 60335-1).
PROGRAMMING
42
The equipment is designed for non enclosed
installations.
For the connection of stiff or flexible tubes
and fasteners, use connectors according to
IP55 protection grade.
WARNING LIGHT DESCRIPTION
The warning light shows in real time
the state of the gate:
STOP → light off
IN PAUSE → light always on
DURING OPENING → the light flashes
slowly (2 Hz)
DURING CLOSING → the light flashes
rapidly (4 Hz)
TERMINAL CONNECTIONS
In order to facilitate the connections, the PD2
control unit is equipped with two entirely
removable terminal blocks.
1. Antenna masquade.
2. Antenna shield.
3. Opening control for the connection
of: push-button panel, key switch
and timer. Contact normally open.
4. Pedestrian opening control for the
connection of:: push-button panel,
key switch and timer. orologio.
Contact normally open.
5. Stop. Contact normally closed.
6. Common (-).
GB
PROGRAMMING
43
7. Photocell 1. Contact normally
closed.
8. Photocell 2. Contact normally
closed.
9. Safety bar 1. Contact normally
closed.
10. Safety bar 2. Contact normally
closed.
11. Common(-).
12. Limit switch during opening.
Contact normally closed.
13. Limit switch during closing. Contact
normally closed.
14.-15. Output power supply 24 Vac for
photocells and other accessories.
16.-17. Pilot lamp 24 Vac 3W.
18.-19. Flashlight 220 Vac 40 W.
20.-21. Contact for courtesy light 220 Vac
10 A.
22. Output motor opening.
23. Common motor.
24. Output motor closing and
connection of the rephasing
capacitor
25. Terminal for the connection of the
rephasing capacitor.
26. Neutral power supply 230 Vac.
27. Power supply phase 230 Vac.
IMPORTANT: it is necessary to connect the
rephasing capacitor between the terminals 24
and 25.
GB
TECHNICAL SPECIFICATIONS
Power supply: 230 Vac; 50Hz
Max motor load: 700 W
Max load accessories
powered at 24V: 10 W
Working environment
temperature: -20°C / +60°C
Protection fuses:
5A for line 230Vac
400mA for line 24Vac
Dimensions: 220x170x80 mm
Weight: 1,65 Kg