Table 83: Keypad control parameters, M3
Index Parameter Min Max Unit Default Cust ID Description
P3.1 Control place 0 3 1 125
0 = PC Control
1 = I/0 terminal
2 = Keypad
3 = Fieldbus
R3.2 Keypad reference P2.1.1 P2.1.2 Hz 0.00
P3.3
Direction (on key-
pad)
0 1 0 123
0 = Forward
1 = Reverse
P3.4 Stop button 0 1 1 114
0 = Limited func-
tion of Stop button
1 = Stop button
always enabled
R3.5 Torque reference -300.0 300.0 % 0.0
6.4.14 SYSTEM MENU (CONTROL KEYPAD: MENU M6)
For parameters and functions related to the general use of the AC drive, such as application
and language selection, customised parameter sets or information about the hardware and
software, see the product's User Manual.
6.4.15 EXPANDER BOARDS (CONTROL KEYPAD: MENU M7
The M7 menu shows the expander and option boards attached to the control board and board
related information. For more information, see the product's User Manual.