Flame goes off during operation and
subsequent
ignition attempts failed Gas supply
temporarily stopped, faulty earthing of
appliance
Fan blocked, plug not inserted correctly
on fan, hall sensor defective, fault in
cable harness, electronics defective
Short circuit on eBUS, overload on
eBUS or two power sources on eBUS
with different polarity
Gas–valve control defective
Short circuit/earth (ground) leak in cable
harness to gas valves, gas valve
assembly defective (earth/ground leak
from coils), electronic control system
defective
Gas valve leaking, electronics defective
Short-circuit in flow or return NTC or
electronics defective
Electronics temperature too high
Electronics too hot due to external
effect, electronics defective
Flame detector input signal is outside
the limits (0 or 5 V)
No valid DSN in display and/or main
board
Spare part failure display and main
board interchanged at same time and
device specific number not adjusted
Flow NTC reports constant value (stuck
at)
Flow and/or return NTC fault
Flow and/or return NTC is defective
(tolerances too big)