4.4.4 Controls
Table 4.2 Vaillant controls (used in conjunction with the VR 65 accessory)
VRT 392 Programmable Room
Control
VRT 392f RF Programmable Room
Control
VRC 470 Weather Compensator
VRC 470f Weather Compensator
(From Q3 2011)
Allows ebus connection of 1 x hot
water and 1 x heating zone
Allows two zone heating systems to
wire to ebus system Note: Wiring
harness plug x2 may be required.
Contact our technical dept for
details.
VR 81/2 Remote Control Unit
Allows remote control of 1 zone or
Temperature control of a second
zone
Allows Weather compensator to
add solar control functionality
4.4.5 External electrical controls
The boiler terminals 3, 4 and 5 are for connecting external electrical controls. Terminals 3 and 4
are linked together when the boiler is supplied. If external controls are used, this link must be
removed, and the controls connected to terminal 4. Terminal 5 is an additional neutral
connection for external neutrals such as from the anticipator of a room thermostat.
4.4.6 Connection details for external switches and boiler terminal strip.
Fig. 4.11 Mains Supply and External Controls