Minimum gas rate
M
3
/h
0.53
0.53
0.56
0.71
Burner % CO
2
(Case on)
%
9.3 + 0.2 -
0.5
9.3 + 0.2 -
0.5
9.3 + 0.2 -
0.5
9.0 + 0.2 -
0.5
Gas connection
(compression)
mm
15
15
15
15
Water connections
(compression)
mm
22
22
22
22
Condensate drain
(internal diameter)
mm
19 min.
19 min.
19 min.
19 min.
Fuse ratings fan supply
PCB
A
3.15 AT
3.15 AT
3.15 AT
3.15 AT
Main PCB
A
125 mAT
125 mAT
125 mAT
125 mAT
Minimum flow rate of
water through the boiler
L/min.
10.8
12.9
20.3
27.2
Weight
kg
3.1
3.1
3.3
3.3
Electrical supply
V˜/HZ
230/˜50
230/˜50
230/˜50
230/˜50
External fuse
A
3
3
3
3
Power input
W
60
60
60
60
Flue categories
C13, C33,
C43, C53
C13, C33,
C43, C53
C13, C33,
C43, C53
C13, C33,
C43, C53
Case height
mm
600
600
600
600
Case width
mm
375
375
375
375
Case depth
mm
334
334
334
334