Warm start temperature target value
(when accessories are fitted) Storage
temperature target value (system boiler
only)
in °C, 40 to 65°C in °C, 15°C for left
stop, then 40 to 70°C
External controls heat demand
(terminals 3-4)
0 = open (no heat request) 1 = closed
(heat request)
Flow target temperature from external
analogue regulator to terminal
7-8-9/eBUS
in °C, minimum from ext. eBUS target
value and target value terminal 7
Status internal heating pump
Status external heating pump
Cylinder charging pump (via accessory
module)
Hot water circulation pump (via
accessory module)
Hot water activation via eBUS Control
Control signal for both gas valves
Position of diverter valve (when
accessories are fitted)
0 = Heating; 100 = Hot water; 40 =
Centre position
Flow temperature Actual value
Return temperature Actual value
Digitised ionisation potential
Display range of 0 to 102, > 80 no
flame, < 40 even flame