d.27
Switching accessory relay 1 in the
accessory module
1 = Circulation pump (default)
2 = Ext. pump
3 = Storage charging pump
4 = Flue gas flap/extractor hood
5 = External gas valve
6 = External error message
d.28
Switching accessory relay 2 in the
accessory module
1 = Circulation pump
2 = Ext. pump (default)
3 = Storage charging pump
4 = Flue gas flap/extractor hood
5 = External gas valve
6 = External error message
d.50
Offset for minimum speed
in rpm/10, adjustment range: 0 to 300
d.51
Offset for maximum speed
in rpm/10, adjustment range: -99 to 0
d.58
From the third quarter of 2006:
Activation of solar reheating
Setting range:
0 to 30 = solar reheating disabled
(factory setting) 3 = activation of min.
hot water target value = 60°C for solar
reheating
d.60
Number of safety temperature limiter cut
offs
Quantity
d.61
Number of lock outs
Number of unsuccessful ignitions in the
last attempt
d.64
Average ignition time
in seconds
d.65
Maximum ignition time
in seconds