For the installer
ecoTEC plus 612
ecoTEC plus 615
ecoTEC plus 618
ecoTEC plus 624
ecoTEC plus 630
ecoTEC plus 637
ecoTEC plus 824
ecoTEC plus 831
ecoTEC plus 837
ecoTEC pro 28
ecoTEC pro 24
Instructions for installation and servicing
ecoTEC
Wall hung room sealed fan assisted condensing boiler
GB

Table of Contents

Questions and Answers

  • M
    Michelle Torres MDAug 30, 2025
    What to do if the water pressure sensor or cable harness hydraulics are defective in my Vaillant ecoTEC plus 831 Boiler?
    • X
      xmurphyAug 30, 2025
      If the water pressure sensor or cable harness hydraulics are defective in your Vaillant Boiler, it could be due to a broken line to the water pressure sensor, a short-circuit at 0 V, or a defective water pressure sensor. Inspect and replace the water pressure sensor or repair the line.
  • B
    Benjamin AlexanderSep 7, 2025
    What does it mean if my Vaillant Boiler shows eBUS undervoltage?
    • L
      Larry AndrewsSep 7, 2025
      An eBUS undervoltage indication means there could be a short circuit on the eBUS, an overload on the eBUS, or two power sources on the eBUS with different polarity. Check the eBUS connections and power sources.
  • C
    crystalbyrdAug 29, 2025
    What to do if there is a short circuit in the flow-NTC of my Vaillant ecoTEC plus 831 Boiler?
    • V
      vegamargaretAug 29, 2025
      If there is a short circuit in the flow-NTC of your Vaillant Boiler, it could be due to the NTC plug shorted to the casing or a defective NTC. Inspect and replace the NTC if defective.
  • P
    Paul PetersonSep 18, 2025
    What does it mean if my Vaillant Boiler water pressure sensor signal is out of range (too high)?
    • V
      vjonesSep 18, 2025
      If the water pressure sensor signal is out of range (too high), the cable to the water pressure sensor has a short-circuit at 5 V / 24 V, or there is an internal fault in the water pressure sensor. Inspect and repair the cable and replace the water pressure sensor.
  • A
    Alicia DanielsSep 8, 2025
    Why is the safety temperature limiter by NTC activated in my Vaillant Boiler?
    • B
      Bethany MartinSep 8, 2025
      The safety temperature limiter by NTC might be activated because the Flow-NTC is not correctly thermal-connected or is defective, causing the appliance not to shut down. Check the thermal connection of the Flow-NTC and replace it if defective.
  • B
    Brad CruzSep 12, 2025
    How to fix Return NTC short circuit in Vaillant Boiler?
    • R
      rachel14Sep 12, 2025
      A Return NTC short circuit can be caused by a defective NTC, a short circuit in the cable harness, or a cable/casing shortcut. Replace the NTC and inspect the cable harness.
  • K
    Katelyn BarronSep 16, 2025
    What to do if my Vaillant Boiler shows flow and/or return NTC fault?
    • D
      Dennis BurtonSep 16, 2025
      If there is a flow and/or return NTC fault, the flow and/or return NTC is defective (tolerances too big). Replace the flow and/or return NTC.
  • S
    samanthahollandSep 23, 2025
    What to do if the gas supply to my Vaillant ecoTEC plus 831 is off?
    • E
      elizabethsanchezSep 23, 2025
      If the gas supply to your Vaillant Boiler is off or not correctly purged, check that the gas supply to the boiler is on, that it has been correctly purged, and that an inlet pressure of 20 mbar is available at the gas valve.
  • S
    Scott RichAug 26, 2025
    Why does the flame go off during operation in my Vaillant ecoTEC plus 831?
    • B
      Barbara FlowersAug 26, 2025
      If the flame goes off during operation and subsequent ignition attempts fail in your Vaillant Boiler, it could be due to a temporarily stopped gas supply, spark failure in the ignition transformer, or faulty earthing of the appliance. Check gas supply and ignition system for faults.
  • M
    Michelle RyanAug 25, 2025
    What to do if my Vaillant Boiler is dry firing?
    • S
      Susan KingAug 26, 2025
      If your Vaillant Boiler is dry firing, it indicates there may be too little water in the appliance, a defective water shortage switch, a defective cable to the pump or water shortage switch, a blocked or defective pump, or the pump output is too low. Ensure adequate water supply and check the water shortage switch and pump.

Summary

Introduction

Notes on the Documentation

Information on the documentation provided for the appliance and general notes for clarity.

General Notes

General information about the boiler's design for sealed central heating systems and mounting.

Boiler Specifications

Technical Data

Detailed technical specifications including output, dimensions, electrical data, and performance figures.

Dimensions

Diagram showing the overall dimensions of the boiler and key connection points in millimeters.

Installation

Diagrams illustrating the function elements of combination and system boilers for installation.

General Requirements

Related Documents

Lists relevant standards, regulations, and documents for boiler installation.

Installation Site

Guidance on selecting a suitable location for the boiler, considering clearances and environmental factors.

Gas Supply

Requirements for the gas supply, including connection, pipework size, and leak checks.

Electrical Supply

Details on the required electrical supply, connection methods, and safety precautions.

Boiler Installation Sequence

Required Minimum Distances;Assembly Clearances

Specifies the necessary clearances around the boiler for installation and servicing.

Gas Connection

Instructions for safely connecting the gas supply to the boiler, including required tools and checks.

Heating Connection

Guidelines for connecting the heating flow and return pipes to the boiler, including pressure relief valve.

Electrical Connection

Detailed instructions for making the electrical connection to the boiler, including wiring diagrams.

Controls

Vaillant Controls and Accessories

List of Vaillant compatible controls and accessories with their connection details.

External Electrical Controls

Information on connecting external electrical controls like time switches and thermostats.

Connection Details for External Time Switches and Boiler Terminal Strip

Schematic showing connections for time switches and room thermostats to the boiler terminals.

Commissioning Part I

Preliminary Electrical Checks

Checks to be performed on the electrical installation before commissioning the boiler.

Gas Supply

Inspection, leak checks, and purging of the gas installation according to regulations.

Filling and Bleeding the Heating System

Procedures for filling the heating system, including checks and bleeding air from radiators.

Initial System Flush (“cold”)

Instructions for flushing the heating system to remove installation debris before boiler commissioning.

Functional Checks (Commissioning Part II)

Functional Checks

Procedures for performing functional checks on the appliance after installation.

Heating

Steps for checking the heating operation, including status indicators and display readings.

Handing Over to the User

Guidance on instructing the user on safe operation, controls, and the importance of regular servicing.

Inspection and Maintenance

Initial Inspection

Recommendations for regular inspection and servicing of the boiler for safe and efficient operation.

Maintenance

Overview of inspection and maintenance tasks to be performed annually and as part of regular servicing.

Servicing the Burner Module

Detailed steps for removing, cleaning, and refitting the burner module components.

Troubleshooting

Logical Fault Finding Procedure

Step-by-step procedure for diagnosing and resolving potential issues with the boiler.

Status Codes

Explanation of status codes displayed by the appliance to indicate operating conditions.

Diagnostic Codes

Information on accessing and interpreting diagnostic codes for fault analysis and parameter adjustment.

Parts Replacement

Safety Instructions

Crucial safety instructions to be followed before replacing any component to prevent damage or injury.

Replacing Burner

Procedure for safely removing and refitting the burner module, including necessary checks.

Replacing Fan or Gas Valve

Steps for replacing the fan or gas valve, emphasizing safety and correct reassembly.

Recycling and Disposal

Vaillant Service

Appendix

EC Declaration of Conformity

Document confirming the appliance's compliance with relevant European directives.

Vaillant ecoTEC plus 831 Specifications

General IconGeneral
ModelecoTEC plus 831
CategoryBoiler
Output31 kW
ERP RatingA
MountingWall-mounted
Boiler TypeCombi
TypeCondensing
FuelNatural Gas
Warranty5 years
Efficiency89.3%
Dimensions720mm x 440mm x 338mm