EasyManuals Logo

Vaillant ecoTEC plus Instructions For Installation And Servicing

Vaillant ecoTEC plus
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
Boiler specifications
8 Instructions for installation and servicing ecoTEC 839592_13
2
Technical data
ecoTEC plus
Units
612 615 618 624 630 637
CH heat output range
80 °C flow/60 °C return
60 °C flow/40 °C return
50 °C flow/30 °C return
40 °C flow/30 °C return
4.9 – 12.0
5.1 – 12.3
5.2 – 12.7
5.3 – 12.9
4.9 – 15.0
5.1 – 15.5
5.2 – 15.9
5.3 – 16.2
6.7 – 18.0
6.9 – 18.6
7.1 – 19.1
7.2 – 19.5
8.7 – 24.0
9.0 – 24.7
9.3 – 25.5
9.4 – 26.0
10.0 30.0
10.3 – 30.9
10.6 –31.8
10.8 – 32.4
12.0 – 37.0
12.3 – 38.1
12.7 – 39.3
12.9 – 40.1
kW
kW
kW
kW
Category II
2H3P
SAP Seasonal Efficiency 89.0 89.0 89.0 88.9 89.0 88.9 %
Inlet gas working pressure required (G20,
natural gas)
20
(mbar)
hPa
Inlet gas working pressure required (G31, Pro-
pane)
37
(mbar)
hPa
Connected load (if needed, related to stored
charge/water heating) at 15 °C and 1013
(mbar) hPa
G20: 1.3
G31: 0.95
G20: 1.6
G31: 1.19
G20: 1.9
G31: 1.43
G20: 2.6
G31: 1.90
G20: 3.2
G31: 2.38
G20: 4.0
G31: 2.94
m
3
/h
kg/h
Exhaust mass rate
at minimum thermal load (40 °C flow/30 °C
return
at maximum thermal load (80 °C flow/60 °C
return)
2.3
5.6
2.3
7.0
3.2
8.5
4.2
11.2
4.8
13.9
5.7
17.1
g/s
g/s
Exhaust temperature
at minimum thermal load (40 °C flow/30 °C
return)
at maximum thermal load (80 °C flow/60 °C
return)
40
70
40
75
40
83
40
70
°C
°C
NOx class 5
Protection class IP X4D
max. flow temperature 85 °C
Adjustable flow temperature
Default setting: max. 75 °C
30 – 85 °C
Maximum CH system pressure (3.0) 0.3
(bar)
MPa
Circulating water volume (
T=20 K) 516 645 774 1032 1290 1591 l/h
Approx. condensation volume
at 50 °C flow/30 °C return heating
1.1 1.4 1.7 2.2 2.7 3.8 l/h
Pump delivery height 250 150
(mbar)
hPa
Adjustable storage target value (15 °C at left
stop, spare adjusting range 40 – 70 °C
15 – 70 °C
Exhaust flue 60/100 mm
Flue categories C13, C33, C43, C53, C83, B23, B33
10 l expansion vessel pre-charge pressure (0.75) 75
(bar)
kPa
Connections heating flow/return 22 mm
Gas inlet 15 22 mm
Pressure relief discharge pipework (min.) 15 mm
Condensate drain (min. internal drain) 19 mm
Dimensions (H x W x D) 720 x 440 x 335
720 x 440 x
369
720 x 440 x
403
mm
Weight (boiler only) 35 35 35 37 38 42 kg
Primary water content 1.9 1.9 1.9 2.1 2.3 2.5 l
Electrical supply voltage 230/50 V ~/Hz
Internal fuse (slow) main voltage 2 A
Power input 100 110 100 110 105 155 W
Table 2.2 T
echnical data ecoTEC system boiler

Table of Contents

Other manuals for Vaillant ecoTEC plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaillant ecoTEC plus and is the answer not in the manual?

Vaillant ecoTEC plus Specifications

General IconGeneral
ModelecoTEC plus
CategoryBoiler
TypeCondensing
Dimensions (H x W x D)720mm x 440mm x 338mm
ErP RatingA
MountingWall-mounted
Output Range12kW to 38kW
Fuel TypeNatural Gas
Domestic Hot Water Output38kW
Flow Rate15.9 l/min
NOx EmissionsClass 5
Efficiency94% (SAP 2009)