Installation and maintenance instructions ecoTEC 0020029172_0314
Model Article
number
Connection
Sizes
1
Header
width
A
Header
depth
B
Total
height
C
Insulation
dimensions
To boiler
D
To heating
circuit
E
Height from
floor
F
Maximum
volume
flow m
3
/hr
WH 40 306720 1
1
/
4
" BSP (f) 115 115 500 115/115 280 340 n/a 3.5
WH 95 306721 2" BSP (f) 155 155 750 155/155 470 540 n/a 8
WH 160 306726 DN65 520* 120 1350 220/220 900 900 300 12
WH 280 306725 DN80 600* 160 1390 260/260 930 930 300 21.5
Table 5.2 Low loss headers dimensions
All dimensions in mm
* = distance between flanges
Fig. 5.1 Low loss header
Safety devices
The outlet of the expansion relief valve must be
suitably terminated in accordance with BS 6798 or
BS 6644.
The boiler is suitable for connection to plastic
centralheating pipes. In this connection preferably
1.5 m copper pipes should be used prior to the
transition to the plastic pipes for the connection to
the boiler.
Should a system be found to include non-oxygen
barrier pipe then it is essential that a plate heat
exchanger be installed in between the boiler and the
non-oxygen barrier pipe, thus preventing corrosion. It
is essential that the boiler and the system have
provision for water make up and expansion.
For more detailed information on examples of systems
and system equipment contact your Vaillant sales
support point.
a
Caution!
The following system diagrams are schematic
representations. They cannot be regarded as a
substitute for professional planning! The
system diagrams do not include the isolator
and safety devices that are required to carry
out a professional installation. Observe the
applicable standards and guidelines.
The boiler can be installed in three different
configurations:
• heat only,
• cylinder only, and
• heating and cylinder.
5.1 Heating mode
In case of only one heating circuit to be operated
downstream of the low loss header, this one can directly
be controlled by the ecoTEC.
A suitable pump can be selected and installed
downstream of the low loss header. You can select a
pump that fits to your system (4 m or 6 m pump or
electronically controlled pump). In case of systems with
multiple circuits please pay additional attention to the
control system accessories.