- 15 -
0020140122_02 - 05/13
TECHNICAL DATA
EN
8 Decommissioning
Switch o the product.
Isolate the product from the power mains.
De-install the product.
Recycle or dispose the product and its components (see
chapter 9).
9 Recycling and disposal
9.1 Recycle the packaging
- Sort the waste to separate those which can be recycled
(cartons, plastics...) from those that cannot (strapping ...).
- Recycle the product packaging according to all relevant
regulations.
9.2 WEEE: Recycle or dispose the product and its
components
The product must be recycled under the WEEE Directive (Waste
Electrical and Electronic Equipment), which speci es:
- the selective collection of waste electrical and electronic
equipment.
- the selective systematic treatment of certain components and
substances considered as dangerous,
- the reuse, recycling and recovery of the collected WEEE.
Do not dispose of your product or any of its
accessories in the household waste.
Make sure the old unit and any accessories are
disposed of properly.
Deposit the product at an appropriate collection point for the
treatment, evaluation and recycling of WEEE.
Observe all relevant regulations.
i
By adhering to this directive, you are helping the envi-
ronment and contributing to the preservation of natu-
ral resources and the protection of human health.
10 Guarantee and customer service
10.1 Vaillant warranty
We only grant a Vaillant manufacturers warranty if a suitably
quali ed engineer has installed the system in accordance with
Vaillant instructions. The system owner will be granted a warranty
in accordance with the Vaillant terms and conditions. All requests
for work during the guarantee period must be made to Vaillant
Service Solutions (0870 6060 777).
10.2 Vaillant Service
To ensure regular servicing, it is strongly recommended that
arrangements are made for a Maintenance Agreement. Please
contact Vaillant Service Solutions (0870 6060 777) for further
details.
11 Technical data
Description Unit VR 66
Power-supply voltage V,Hz 230,50/60
Power consumption W 20
Contact load of output relays (max.) A 2
Delay fuse A T 4A/250V
Contact voltage for DHW cylinder
thermostat
V 230
Temperature sensor (NTC)
operating voltage
V5
Thermistor NTC at 25°C kOhm 2,7
eBUS connection cable gauges mm
2
2 x 0.75
Maximum length of eBUS cable m 300
Power cable gauge mm
2
3 x 1.5
Maximum length of power cable m 10
Dimensions :
Height mm 185
Length mm 281.3
Depth mm 49.5
Electrical protection IP20
Electrical classi cation I