to OFF and try again.
In the unlikely event of failure of the ignition mechanism the pilot can be lit with a
long match or taper – See the next page.
When the pilot has lit keep the knob depressed for about ten seconds to allow the
flame sensing probe to warm up.
The control knob can then be set to your preferred heat level. The settings are:
To turn off partially depress the knob and turn clockwise to off. Wait at least three
minutes before attempting to relight.
Lighting with a match or taper
Depress the control knob and turn anticlockwise towards the 1/IGN position.
While keeping the knob depressed, light the pilot by inserting a long match or
taper into the pilot viewing opening (See figure 3).
When the pilot is alight, keep the knob depressed for about ten seconds to allow
the flame sensing probe to warm up before setting to your preferred heat level.
For your own convenience, have the heater serviced as soon as possible.
Page 8
OWNER GUIDE
Knob
Position
Radiants Condition
2 Centre radiant on low. Outer radiants off.
3 Centre radiant fully on. Outer radiants off.
4 Centre radiant fully on. Outer radiants on low.
5 All radiants fully on.