1 Overview
This guide describes the installation of the ACTpro-100 door stations, which are compatible with all
ACTpro controllers.
The ACTpro-100 is a single door station.
The ACTpro-1002A is a single door station with a 12V DC 2A PSU.
1.1 Technical specification
ACTpro-100 ACTpro-1002A
Input Voltage Range 12V DC 12V DC
Current Consumption 40120 mA 40120 mA
Operating Environment Surface mounting
Internal use only
Surface mounting
Internal use only
Operating Temperature -10 to +50° C -10 to +40° C
75% RH non-condensing
Dimensions (H x W x D mm) 165 x 235 x 55 275 x 330 x 80
Weight (kg) 0.4 2.2
Enclosure Material ABS 1.2mm steel grey powder coated
LED Status Indicators Yes Yes
PSU Fault Output n/a Yes
Lid Opening Tamper Detection (Front) Yes Yes
Rear Tamper Detection No Yes
1.1.1 ACTpro-1002A electrical specification
Battery charging Yes
Standby Battery 12V 7Ah Battery
Battery Deep Discharge
Protection
No
Input: Voltage Rated 100240V AC
Input: Voltage Operating 90264V AC
Input: Frequency 5060Hz
Input: Max Current 1.0A (@ 90V AC)
Input: Mains input fuse T2.0A
Input: Max standby power 0.5W (no load and no battery connected)