Output: Voltage 13.4–14.2V DC (13.8V DC Nominal) on mains power
Output: Max load current 2.0A
Output: Ripple 150mA pk–pk max
Output: Load output fuse F2.0A
Output: Overload Electronic shutdown until overload or short circuit removed (Under mains
power only)
1.1.2 Relay load
When used with inductive loads (Maglock/Strike locks) the following ratings apply.
ACTpro-100 ACTpro-1002A
Main relay 1.5A @ 30VDC /
1.5A @ 50VAC
1.5A @ 30VDC /
1.5A @ 50VAC
Aux relay 400mA @ 30VDC 400mA @ 30VDC
1.2 Ordering details
ACTpro-100 V54502-C120-A100 Single door station
ACTpro-1002A V54502-C121-A100 Single door station with 12V DC 2A PSU
1.3 Monitoring
All faults including Mains Present and Tamper are reported on the ACT Enterprise software.
Mains present The PSU MAINS PRESENT output, when available, is pre-wired to the MAINS PRESENT
input.
Output Voltage The PSU output voltage level is reported to the ACT Enterprise software.
Tamper The enclosure lid is tamper monitored.
ACTpro-100 / ACTpro-1002A – Installation and Operating Instructions Overview