5
Electrical
Specification Model No.
Item LSC12-2000
AC Input* 30 A MAX
Power Factor
Correction(PFC)
>0.95 (Max.)
Auxiliary DC
Output
Output Voltage Battery Voltage
Output Current 20A Max
DC Output
Characteristics
Range
25 / 50 / 75 / 100A
Max. Output
Voltage
14.4 VDC
Battery Control (3-
stage Battery
Chargers)
Bulk / Absorption / Float
Signal and
Control
Remote Control
Terminal
Controls the inverter ON / OFF operation
Dry Contact
Terminal
By a relay
Bypass Relay
Relay Specification
30 Amp / 250 VAC
Transfer Time
0 sec
Operating Temperature
Range
Full Load -20 ℃ ~ 40 ℃
Power de-rating 60 W / ℃, 41~60 ℃
Storage -30 ℃~70 ℃
Operating Humidity
Range
Max 93%, Non-condensing
Cooling
Temperature & Load Controlled Cooling Fan
Mechanical Specification
251 x 116 x 453mm
Net Weight 6 Kg
Safety and EMS
Safety Standards UL458 Vehicle & Supplement SA
EMC Standards Certified FCC Class A*
Table 3. LSC Series Specification
Note :
1. Max Inverter output define inverter 100% load output at Vac =100V / 200V
2. Max AC input current Limit by the Breaker
3. LSC12-2000 is a class A product. In a domestic environment this product may cause radio interference in which case the user may
be required to take adequate measures.