12
Do not apply heat to brass fittings.
6. WATER SUPPLY CONNECTIONS
See INSTALLATION DIAGRAM 1 on page 20 and INSTALLATION
DIAGRAM 2 on page 20.
Do not over tighten brass threads.
Do not apply heat to brass fittings.
Mark the water shutoff for future reference.
If there is a check valve (sometimes in water meter), backflow
preventer or pressure-reducing valve, install an adequate size
expansion tank.
7. FILLING THE HEATER
Water connections completed and free of leaks.
Check for proper installation of the temperature and pressure relief
valve.
Close drain valve.
Open the highest hot water faucet.
Open cold water inlet valve and fill system.
8. WIRING
Verify that wiring matches thermostat diagrams.
Check that water heats to desired temperature.
9. INSTALLATION COMPLETED AND CHECKLIST FILLED
OUT
BY: ____________________________________________________
DATE: _________________________________________________
NOTES: ________________________________________________