10
D) Hardwire Terminal Block: When the load current is >15A, must use output terminal connection.
a) AC Input Terminal Block: a screw type terminal block for attaching AC output
wires. Each slot is labeled L for Lines and N for Neutral. Connect the incoming
Line wire to the input L slot, Connect the incoming Neutral wire to the input N slot.
b) AC Output Terminal Block: a screw type terminal block for attaching AC output
wires. Each slot is labeled L for Lines and N for Neutral. Connect the outgoing Line wire to
the output L slot, Connect the outgoing Neutral wire to the output N slot.
E) Fuse breaker: under “bypass mode”, when the AC output is shorted or the load current exceeds the
rated current of the fuse breaker, the fuse breaker will burned to stop bypassing energy from the utility
getting to present possible danger.
F) Ventilation holes: the inverter requires suitable ventilation to work properly.
Please make sure there is good ventilation and the lifespan of the inverter
can preserved.
H) Communication port: for remote control purpose, the unit can be connected a remote control panel
by using the optional cable
I) Led indication: Operating status, warning
a. Inverter: The inverter started up and output is normal.
b. Fault: Warning user there is some problem, need to check the system now.
Such as low voltage, over voltage, over load, short circuit and so on.
c. AC in: The status of utility is normal.
d. Bypass: The unit is working under “bypass mode”, the AC electricity consumed by the loads is
provided by the utility instead of the inverter.
11. INSTALLATION
Connections & Operations
Step 1 Connect the (+) and (-) cables from the battery to the respective terminals
of the unit.
Step 2 Plus in the AC source to real panel AC Input Socket(Hard Block Terminal)
Step 3 Connect the earth cable from the AC ground system to that of the unit
Step 4 To start the unit, turn on the ON/OFF switch. LED green lights on,
Charger and AC power on.
Step 5 Connect consumer unit to the socket in the front of the unit
Step 6 Make sure the cable is firmly connected in the socket. If the connection
is not firm enough, the plug will heat up and cause unit damage
Step 7 USB only supply output power source
Warning: the output voltage of this unit must never be connected in it's input
AC terminal, overload or damage may result. Always switch on the inverter
before plugging in any appliance. Damage caused by AC wiring mistakes are
not covered under warranty .