12
Power ON/OFF Switch
A. Power ON/OFF switch is to turn the inverter on or off.
Battery Capacity/Load Voltage indicator
B. Load: Show the approximate connected equipment load level.
5 Levels---20%,40%,60%,80%,100%.
C. Battery: Show the battery residual capacity.
5 Levels---20%,40%,60%,80%,100%.
AC In Indicator
D. AC In: after correct connect the AC mains , the light will turn on.
E. Bypass: under Bypass function, the light will on .
Charge In: Under charge function ,the light will on
F. Fault: Turns red show fault, refer to Troubleshooting of Inverter Manual.
Connecting the Communications Cable
The communications cable is 3meters, 6-conductor cable (wired like a normal telephone-type cable).
This cable is connected to the RJ11 jack on the rear of the remote control and to the REMOTE port
located on the rear of the inverter.
Notice:
Inverter's ON/OFF Switch and Remote control's ON/OFF Switch is in parallel. To use this
remote control, must turn the inverter's ON/OFF Switch to OFF, and vice versa.
13. WARRANTLY
We guarantee this product against defects in materials and workmanship for a period of 18 months
from the date of retail purchase by end user.
This warranty will be considered void if the unit has been misused, altered, or accidentally
Damaged .We are not liable for anything that occurs as a result of the user’s fault.
If the warranty period for your product has expired, if the unit was damaged by misuse or
incorrect installation, if other conditions of the warranty have not been met, or if not dated proof
of purchase is available, your unit may be serviced or replaced for a flat fee.