Provides an overview of the MS-40 Operations & Maintenance Manual.
Instructions for safely unpacking and inspecting the MS-40 leak detector.
Details the requirements and procedures for properly installing the MS-40.
Lists the technical features and specifications of the MS-40 leak detector.
Provides a general overview of the MS-40's capabilities and modes of operation.
Describes the normal operating procedures for the MS-40 user panel and controls.
Explains how to enter and the purpose of the Service Mode for advanced operations.
Introduces the chapter on operating the MS-40 and its sections.
Details the function of each control and indicator on the MS-40 user panel.
Outlines the procedure for starting up the MS-40 and its self-diagnostic sequence.
Explains the process of performing leak tests using the MS-40.
Describes how to operate the MS-40 with an external pump for enhanced performance.
Details the correct procedure for safely shutting down the MS-40 unit.
Explains how to adjust various test parameters to optimize leak detection.
Describes how to set the pressure point for switching between gross and reverse modes.
Describes how to set the pressure point for switching between reverse and direct modes.
Explains how to define the leak rate threshold for accept/reject indications.
Details how to adjust time intervals for valve operations to customize test cycles.
Covers the adjustment of advanced parameters like Amplifier Gain.
Explains how to set amplifier gain for compensating sensitivity changes during calibration.
Covers useful tools and procedures like Auto Zero and Peak Scan.
Describes the Peak Scan function for verifying spectrometer tuning.
Explains the Cal-Check function to verify measurement accuracy.
Details the Auto Tune procedure for optimizing mass spectrometer performance.
Explains fundamental principles of leak detection and standards for permissible leakage.
Describes the operational theory behind Direct Flow and Reverse Flow modes.
Explains the Direct Flow mode for high sensitivity and clean testing.
Explains the Reverse Flow mode for high out-gassing or fast crossover testing.
Details the functional steps of a basic test cycle, including vacuum system status.
Provides a breakdown of the MS-40's main sub-systems and components.
Describes the mass spectrometer's role in detecting and measuring helium tracer gas.
Lists and describes the components within the MS-40's valve block assembly.
Details the different types of pumps used in the MS-40 system.
Introduces the chapter on MS-40 maintenance, contamination, and troubleshooting.
Explains how to enter and operate the unit in Service Mode for maintenance procedures.
Guides the user through automatic and manual calibration and tuning procedures.
Outlines routine maintenance tasks required for the MS-40.
Details the procedure for inspecting and greasing the test port O-ring for proper sealing.
Instructions for checking the oil level and condition in the MS-40's pumps.
Provides step-by-step instructions for changing the oil in the unit's pumps.
Discusses vacuum system contamination, its causes, effects, and indications.
Lists symptoms that indicate potential contamination within the MS-40's vacuum system.
Explains the critical procedure for safely venting the MS-40's vacuum system.
Details the procedures for cleaning contaminated components of the vacuum system.
Outlines the steps for disassembling and cleaning affected vacuum system components.
Specifies which components require calibration after service or replacement.
Step-by-step guide for calibrating the test port Pirani gauge.
Step-by-step guide for calibrating the fore-line Pirani gauge.
Covers general service procedures and specific repair instructions for components.
Explains how to service various valves in the MS-40, addressing common causes of leaks.
Provides instructions for replacing the filaments in the MS-40's mass spectrometer.
Details the procedure for replacing the unit's circuit boards.
Offers guidance on identifying and resolving system errors and faults.
Introduces the chapter detailing spare parts and component listings for the MS-40.
Lists recommended spare parts with their VIC part numbers for the MS-40.
Provides detailed listings of vacuum system and valve block components.
Lists components of the MS-40 vacuum system with part numbers and descriptions.
Lists components of the MS-40 valve block assembly with part numbers and descriptions.
Defines key terms used in leak detection practices and the manual.
Presents standards from the American Vacuum Society relevant to MS leak detector testing.
Details background, drift, and noise definitions relevant to leak detector calibration.
Defines various types of leaks and leak rate measurements.
Defines terms related to leak detector sensitivity, including minimum detectable signal.
Covers standards related to scans, peak width, and resolution in mass spectrometry.
Provides tables for converting between common units of pressure and leak rate.
A chart for converting pressure values between various units.
A chart for converting leak rate values between different units.
Details the communication protocol and commands for remote PC control of the MS-40.
Describes the function and settings of the profile switches on the MS-40.
Explains the function and settings of the revision switches on the MS-40.
A quick reference guide to the functions and modes of the MS-40 User Control Panel.
A quick reference guide to the functions and modes of the MS-40 Service Panel.
A summary of MS-40 error codes, their descriptions, and suggested actions.
A quick reference for recommended periodic maintenance tasks for the MS-40.