EasyManua.ls Logo

Veeder-Root TLS-350 - Page 50

Veeder-Root TLS-350
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ISD Reports Viewing ISD Reports via RS-232 Connection
44
Balance Systems - Hose No Test Result
If the Flow performance did not run, then an N is posted.
If there were no events received to make any conclusion about the A/L value for the hose, the A/L value is
replaced with an N.
If there are some events received, enough to calculate an average, but not enough to complete a test, the No
Test result will appear with an A/L average.
Balance Systems - Hose Pass Result
When none of the above results, W, F, G, N appear, then it was a pass.
Balance Systems - Code Precedent (Listed high to low)
1. G,F - Flow Collect Failure (A/L) and Statistical Failure (BLKD).
2. W - Flow Collect Warning (A/L and Statistical Warning (BLKD).
3. PASS -Pass Flow Performance Test.
4. N - No Test - Flow Performance Test not completed.
Balance systems - Self Test Codes
ISD-W - A self-test warning condition exists. See ISD Setup.
ISD-F - A self-test warning condition persisted for 7 days and resulted in a Failure.