WS3080
V. 05 – 08/11/2016 8 ©Velleman nv
reset max
(both outdoor temperature [12] and max icon (between [14] and [15])
are flashing)
press and hold the ENTER button for ±3s to reset max value to current
measurement
reset min
(both outdoor temperature [12] and min icon (between [14] and [15])
are flashing)
press and hold the ENTER button for ±3s to reset min value to current
measurement
UV index
Refer to §8.2 for more information.
high alarm
set the high alarm level
Press the ALARM ON/OFF button to enable/disable the alarm. When enabled,
the alarm icon appears.
reset max
(both UV index [15] and max icon (between [14] and [15]) are flashing)
press and hold the ENTER button for ±3s to reset max value to current
measurement
Wind
wind speed
select between average or gust wind speed (default = average)
speed unit
select between km/h, mph, m/s, knots or bft (Beaufort) (default = mph)
high alarm
set the high alarm level
Press the ALARM ON/OFF button to enable/disable the alarm. When enabled,
the alarm icon appears.
direction alarm
set the wind direction alarm
Press the ALARM ON/OFF button to enable/disable the alarm. When enabled,
the alarm icon appears.
reset max
(both wind speed [14] and max icon (between [14] and [15]) are
flashing)
press and hold the ENTER button for ±3s to reset max value to current
measurement
Light
light unit
select intensity unit between fc and lux
high alarm
set the high alarm level
Press the ALARM ON/OFF button to enable/disable the alarm. When enabled,
the alarm icon appears.
reset max
(both light intensity [17] and max icon (between [14] and [15]) are
flashing)
press and hold the ENTER button for ±3s to reset max value to current
measurement
Rain
display mode
select between 1h, 24h, 1 week, 1 month or total
unit
select between mm and inch (default = mm)
high alarm
set the high alarm level
Press the ALARM ON/OFF button to enable/disable the alarm. When enabled,
the alarm icon appears.
reset max
(both rain value [16] and max icon (between [14] and [15]) are flashing)
press and hold the ENTER button for ±3s to reset max value to current
measurement
reset total
(the rain value [16], TOTAL and CLE [4] are flashing)
press and hold the ENTER button for ±3s to reset TOTAL value to current
measurement
Use the HISTORY button [f] to enter the base station memory.
Note: the default interval for data memory is 30 minutes. This interval can only be changed via the
software (refer to the section PC connection).
Use the [d] button to scroll down through the memory, use the [c] to scroll up.
Note: when the end of the memory is reached, the base station returns to normal display.
To clear the complete memory, press the ENTER button [b]. The word CLE [4] and the memory indicator
[5] will start flashing. Press and hold the ENTER button [b] for ±3s to erase the memory.
Note: to save a copy of the memory on a PC, refer to the section PC connection.