10
Hall Effect Type
Configuring the Secondary Trigger (Cam)
The secondary trigger is most often used for cam sync. This can be configured on the Base Setup menu
under the Secondary Trigger Settings item. Mode is either Disabled or Cam-Sync except under special
circumstances. Use rising edge for VR sensor. Either edge can be used for a Hall sensor, but typically
falling is used. Event at Bad Trigger Position is the last common item to configure. It is recommended to
set it to Just Show. You can have it disable injection if you wish, but it is not recommended.
Temperature Sensors
VEMS uses two temperature sensors: Inlet Air Temperature which is used in speed/density systems to
calculate the amount of fuel required. And Coolant Temperature which is used to meter the required amount
of warm-up fuel enrichment.