POSSIBLE PROBLEM POSSIBLE CAUSE SERVICE SUGGESTION
Money accepted, no
product vended
Bad selection switch(es) Check selection switches,
replace as necessary.
Bad selection switch harness
connection
Check harness connection.
Sold-out switch (of column
selected) inoperative
Check switch, replace as
necessary.
Vend motor runs until two or
three products are vended
or vend motors run
continuously
Improper cam lobe
adjustment
Check cam for proper
arrangement of cam lobes
(see product set-up guide).
Motor position switch not
making proper contact with
cam lobe
Check lever for proper lever
positioning and freedom of
movement.
Refrigeration unit will not
run at all
No power to vendor Check power supply, also
check service cord
connections.
Bad temperature sensor Check / replace.
Bad refrigeration relay Check / replace.
Compressor will not start Overload Protector
inoperative
Check overload (apply
insulated jumper across
terminal, if compressor
starts, replace overload).