3/2002
PC-6
ERROR CODES
Open door error code status (as displayed) Detailed error codes are cleared by
pressing selection button 2 for 2
seconds when displayed or
Summary level error codes (as displayed) automatically by the following:
Detail level error codes (as displayed)
DESCRIPTION
nonE No errors exist
Eror One or more errors exist
COLJ
Vend mechanism summary error
CJXX
Column jam in column XX Complete a test for column XX
SELS
Selection switch summary error
SSXX
Selection switch XX is stuck closed Switch XX opens
StS Space-to-sales summary error
UCXX
Column XX is not assigned to a selection Column XX is assigned
USXX
Selection switch XX is not assigned Selection XX is assigned
CHnG
Coin changer summary error
CC Changer communication stopped Changer communication normal
tS Tube sense error reported by changer Changer corrected
IC Changer inlet chute blocked Coin is sensed
tJ Pay out tube jam reported by changer Changer corrected
CrCH
Check sum error reported by changer Changer corrected
EE Excessive escrow attempts Coin is sensed
nJ Coin jam reported by changer Changer corrected
LA Coin acceptance rate is low Coin acceptance rate improves
dIS Unconnected acceptor reported by changer Acceptor properly connected
rout Coin routing error reported by changer Coin is routed properly
bUAL Bill validator summary error
bC Validator communications stopped Validator communications normal
bFUL Bill stacker full reported by validator Bills removed from stacker
bILL Defective motor reported by validator Validator corrected
bJ Bill jam reported by validator Validator corrected
brCH Check sum error reported by validator Validator corrected
bOPn Bill stacker open reported by validator Validator corrected
bS Bill sensor error reported by validator Validator corrected
Crdr Card reader summary error
CrC Reader communications stopped Reader communications normal
CrXY Error *code X, sub-code Y reported by reader Reader corrected
rFrG Refrigeration system summary error
SEnS
Temperature sensor unplugged/defective Sensor connected/replaced
CnPr Cooling system not cooling System cooling at least 1ºF per hour
Htr Heating system not heating System heating at least 1ºF per hour
OtHr Other vendor summary errors
dS Door open for 1 hour Door Closed
rAn Check sum error for service mode setting Any service mode setting changed
ACLO
AC voltage is low
SF Scale factor incompatibility Scale factor is located
IS Vendor inlet coin chute sensor is blocked Blockage is removed
Ib Vendor inlet coin chute is blocked Coin is detected by the changer
Figure 2